Skip to content

CPM-80-25 Measured Performance Data

Status: Public engineering reference
Source: SigGear CPM-80-25 catalogue dynamometer data

The data below contains representative measured points from CPM-80-25 dynamometer testing at 24 V, 36 V and 48 V. These are test observations, not guaranteed continuous operating points.

Actual results depend on controller settings, current limit, thermal state, duty cycle, assembly configuration and test setup.

Test Conditions

Test Ambient temperature
24 V data set 28.4 C
36 V data set 28.8 C
48 V data set 28.5 C

Representative 24 V Points

Speed (rpm) Torque (Nm) Output power (W) Voltage (V) Current (A) Input power (W) Efficiency
127.49 0.0000 0.000 24.013 0.0000 0.000 0.00%
112.99 1.9027 22.511 24.011 1.3995 33.598 67.00%
58.241 29.385 179.21 24.002 20.852 500.56 35.80%
0.0000 58.622 0.000 23.993 41.547 997.32 0.00%

Representative 36 V Points

Speed (rpm) Torque (Nm) Output power (W) Voltage (V) Current (A) Input power (W) Efficiency
191.98 0.0000 0.000 36.014 0.0000 0.000 0.00%
167.51 2.8982 50.835 36.009 2.2257 80.133 63.44%
87.701 32.946 302.55 35.991 24.354 876.73 34.51%
0.0000 65.965 0.000 35.971 48.671 1752.1 0.00%

Representative 48 V Points

Speed (rpm) Torque (Nm) Output power (W) Voltage (V) Current (A) Input power (W) Efficiency
174.66 0.0000 0.000 47.980 0.0000 0.000 0.00%
156.39 1.9679 32.227 47.973 0.9662 46.352 69.53%
80.590 31.982 269.89 47.946 15.201 728.99 37.02%
0.0000 63.892 0.000 47.917 30.336 1454.7 0.00%

Interpretation

Do not use stall points as continuous operating ratings. The public rated output torque remains 10 Nm and peak output torque remains 50 Nm for preliminary product selection. Confirm the required torque-speed cycle and peak duration for the actual project.

CPM-80-25 Technical Datasheet Request Engineering Review